IPPL model Industrial Positive Pressure is a double wall stainless steel chimney with 2″ air space.
Documents
Data sheets
Features
  • Inner wall: 316L or 304 2B stainless steel (20 ga – 6” (152 mm) to 40” (1016 mm) diameter; 18 ga – 42” (1067 mm) to 48” (1219 mm) diameter).
  • Outer wall: 301, 430, 316L, 304 2B stailess steel or galvalume (24 ga – 6” (152 mm) diameter; 20 ga – 42” (1067 mm) to 48” (1219 mm) diameter).
  • Continuous laser welding.
  • Full range of accessories including elbows, fittings, guides and supports.
Weights and Clearances
IPPL LINEAR WIEGHT
I.D O.D AREA IPPL
in mm in mm in2 mm2 lb/ft kg/m
6 152 10 254 28 18.2 5.4 8
8 203 12 305 50 32.4 6.8 10.1
10 254 14 356 79 50.7 8.2 12.2
12 305 16 406 113 73 9.6 14.3
14 356 18 457 154 99.3 11 16.4
16 406 20 508 201 129.7 12.5 18.5
18 457 22 559 254 164.2 13.9 20.6
20 508 24 610 314 202.7 15.3 22.7
22 559 26 660 380 245.2 16.7 24.8
24 610 28 711 452 291.9 18.1 26.9
26 660 30 762 531 342.5 19.5 29.1
28 711 32 813 616 397.3 20.9 31.2
30 762 34 864 707 456 22.4 33.3
32 813 36 914 804 518.9 23.8 35.4
34 864 38 965 908 585.8 25.2 37.5
36 914 40 1016 1018 656.7 26.6 39.6
38 965 42 1067 1134 731.7 28 41.7
40 1016 44 1118 1257 810.7 29.4 43.8
42 1067 46 1168 1385 893.8 30.8 45.9
44 1118 48 1219 1521 981 32.3 48
46 1168 50 1270 1662 1072.2 33.7 50.1
48 1219 52 1320 1810 1167.5 35.1 52.2
MINIMUM CLEARANCE AIR SPACE TO COMBUSTIBLE CONSTRUCTION
MODEL IPPL
Inside diameter Clearance
(1000ºF et 1400ºF)
6'' to 12'' 4''
14'' 5"
16'' to 18'' 6"
20'' to 24'' 7''
26'' to 28'' 8''
30'' to 34'' 9''
36'' to 38'' 10''
40'' to 48'' 11''
Listing

CHEMINEE LINING.E inc. venting systems models IPPL, IPPL2, IPPL2F and IPPL4F are listed by Underwriters Laboratories, inc. (UL) under file MH26661 and tested in accordance with UL 103 Standard for Factory-Built Chimneys for Residential Type and Building Heating Appliances and the Canadian Standard for 540°C (1000°F) and 760°C (1400°F) industrial Chimneys CAN/ULC-C959. These models are also suitable for use in positive pressure applications up to 60” water column. Listings include the following chimney product categories and diameters..

logo_ul-1.gif
UL 103 & CAN/ULC C-959
Models IPPL• IPPL2 • IPPL2F • IPPL4F Temperature Diameter
Building Heating Appliance Type Chimney 1000°F continuous 6" to 48" ID
1400°F Chimney (Models IPPL,IPPL2F and IPPL4F only) 1400°F continuous 6" to 48" ID
Applications
  1. Building Heating Appliance Chimney Listing (1000°F Chimney Listing) – under this category, models IPPL, IPPL2,IPPL2F and IPPL4F, have been determined suitable for venting flue gases at a temperature not exceeding 540°C (1000°F) under continuous operating conditions, from gas, liquid, oil or solid fuel fired appliances.
  2. Building Heating Appliance Chimneys are suitable for use with Building Heating Appliances and Low Heat Appliances as described in the Chimney Selection Chart of National Fire Protection Association (NFPA) Standard No. 211.
  3. 1400°F Chimney Listing – under this category, models IPPL, IPPL2F and IPPL4F, have been determined suitable for venting flue gases at a temperature not exceeding 760°C (1400°F) under continuous operating conditions. As such, they are suitable for use with ovens and furnaces as described in the Chimney Selection Chart of NFPA No. 211, in addition to other applications.
Criteria Grease Duct Restaurant BHA Chimney 1400°F Chimney
Application Cooking Appliances, Ventilation Hoods, Restaurant Grease Ducts & Pizza Oven Exhausts Low and High Pressure Steam Boilers, Diesel and Turbine, Exhausts & Building Heating Equipment Industrial furnaces, Processing Equipment, Kilns and Ovens, Incinerator, Coffee Roaster & Diesel and Turbine Exhaust
Continuous operating temperature 500°F 1000°F 1400°F
IPPL Yes Yes Yes
IPPL2 N/A Yes N/A
IPPL2F Yes Yes Yes
IPPL4F N/A Yes Yes