Lengths

 


Straight Lengths (48L, 36L, 24L et 12L)

Available in 22 diameters from 6 to 48” (152 to 1219mm). Standard lengths: 48” (1219mm), 36” (914mm), 24” (610mm) and 12” (305mm).

Includes: 1- Assembly Band (AB)
  1- Finishing Band (FB)

K=0.30 L/D
L=Pipe length in feet
D=Pipe diameter in inches

 
I.D. O.D.
in mm in mm
6 152 10 254
8 203 12 305
10 254 14 356
12 305 16 406
14 356 18 457
16 406 20 508
18 457 22 559
20 508 24 610
22 559 26 660
24 610 28 711
26 660 30 762
28 711 32 813
30 762 34 864
32 813 36 914
34 864 38 965
36 914 40 1016
38 965 42 1067
40 1016 44 1118
42 1067 46 1168
44 1118 48 1219
46 1168 50 1270
48 1219 52 1321
LENGTHS
EFFECTIVE LENGTHS "A"
in mm
12" (305mm) 11.000 279
24" (610mm) 23.000 584
36" (914mm) 35.000 889
48" (1219mm) 47.000 1194


Variable Length (VL)

Used to absorb linear expansion between two fixed points on low pressure applications.

Includes: 1- Assembly Band (AB)
  1- Outer wall 36” (914mm) long
  2” (51mm) of insulation for IPPL2 and IPPL2F systems

K=Same as pipe length


Ajustable Length (AL)

Used to complete on site installation precisely. It is not designed to compensate for linear expansion nor to support the vertical load of the chimney.

Includes: 1- Assembly Band (AB)
  1- Outer wall 36” (914mm) long
  2" (51mm) of insulation for IPPL2 and IPPL2F systems

K=Same as pipe length


Drain Section (DS)

Used to collect rainwater or condensation water from inside vertical or horizontal flue. To be connected to a drain of 3/4”ø (19mm) - NPT.

Includes: 1- Assembly Band (AB)
  1- Finishing Band (FB)

K=Same as pipe length